Class TransformerSpecification
The data that describes a transformer loss model.
Namespace: SolarFarmerApi.Client
Syntax
public class TransformerSpecification
Properties
FullLoadOhmicLoss
The full-load ohmic loss, also refereed to as "copper loss", in W
The is the part of the losses that is dependent on input power, so specified here for the full power case.
Note: The total loss under full load is FullLoadOhmicLoss + NoLoadLoss, so if a data sheet specifies a global loss under
full load, then the no load losses need to be subtracted to derive the FullLoadOhmicLoss.
Required if ModelType is NoLoadAndOhmic
Declaration
public double? FullLoadOhmicLoss { get; set; }
Property Value
Type | Description |
---|---|
System.Nullable<System.Double> |
LossFactor
The transformer loss as a simple factor or 1
A value of 0.01 would represent a loss of 1%
Required if ModelType is SimpleLossFactor
Declaration
public double? LossFactor { get; set; }
Property Value
Type | Description |
---|---|
System.Nullable<System.Double> |
ModelType
The loss model type, "SimpleLossFactor" or "NoLoadAndOhmic"
Declaration
public TransformerLossModelTypes ModelType { get; set; }
Property Value
Type | Description |
---|---|
TransformerLossModelTypes |
NoLoadLoss
The no-load losses, also referred to as the "iron loss" or "core loss", in W
This is the loss exhibited when the transformer is connected to the grid voltage, but there is input power.
It is mainly caused by hysteresis and eddy currents in the core.
Required if ModelType is NoLoadAndOhmic
Declaration
public double? NoLoadLoss { get; set; }
Property Value
Type | Description |
---|---|
System.Nullable<System.Double> |
RatedPower
The rated power, in W
Required if ModelType is NoLoadAndOhmic
Declaration
public double? RatedPower { get; set; }
Property Value
Type | Description |
---|---|
System.Nullable<System.Double> |